Nominal Input Voltage:
110 VDC / 125 VDC / 144 VDC / 220 VDC / 264 VDC / 360 VDC
Nominal Input Frequency:
50 hz. ±
Total harmonic Distortion (THDi):
&le
Nominal DC Voltage:
110 VDC / 125 VDC / 144 VDC / 220 VDC / 264 VDC / 360 VDC
Battery Charging Principle:
Constant Current / Constant Voltage
Float Charge Voltage (V/Cell):
2,4 Lead Acid Battery 1,60 NiCd Battery (Based on battery brand and type)
Boost Charge Voltage (V/Cell):
2.23 Lead Acid Battery 1,40 NiCd Battery Based (Based on battery brand and type)
Measurements:
LCD Display for Line Voltage / Frequency / Current (Standard in 1 Phase, Optional for 3 Phase), Battery Output Voltage / Current, Load Output Voltage, Charger Total Output Current
Indicators:
Float Mode, Boost Mode, Current Mode, Equalize Mode, Battery Ending, Low Battery, Battery Test Failure, Line Failure, Fan Failure, Over Voltage, Under Voltage, Over Temperature, Rectifier Failure, SCR Fuse Failure, Mains Available, Load MCB, Battery MCB
Adjustable Parameters:
Float Charge Voltage, Boost Charge Voltage, Equalize Charge Voltage, Battery Charge Current, Rectifier Total Output Current, Low Battery Voltage Alarm, Earth Fault Leakage Current Alarm (only available in 4 line LCD), Battery Ending Voltage Alarm, Online Battery Test Parameters, Auto Boost Charge Parameters, Password
Event History:
Last 250 events recorded and displayed on front panel and on PC via RS 232
Open or closed free alarm contacts:
Low Battery, Mains Input Normal / Failure, Charger Failure, Overtemperature, Charger Overvoltage, Load MCB ON/ OFF, Battery MCB ON / OFF, Earth Fault
Sound Alarm:
On Warning Messages 2 Short &lsquo
Isolation Transformer:
Galvanically Isolated (standard)
Nominal Output Voltage:
110 VAC / 220 VAC / 230 VAC / 240 VAC / 380 VAC / 400 VAC / 415 VAC / 480 VAC
Dynamic with 100% load change:
±
Waveform:
Pure Sinusoidal
Total harmonic Distortion (ThDv):
 
Nominal Output Frequency:
 
While synchronized with the line:
50 Hz / 60 Hz ±
While not synchronized with the line:
50 Hz / 60 Hz ±
Switching Frequency:
16 Khz.
Short-circuit behaviour:
3 x Nominal Output Current
Protection:
Short Circuit Protection, Over Voltage Protection, Under Voltage Protection, Over Current Protection and Over Temperature Protection
Front Panel Indicatiors:
Inverter not Synchronized, Inverter DC Input High/Low, Bypass Out of Limit, Battery Fuse OFF, Bypass MCB OFF, DC Input MCB OFF, Inverter Overload, Internal Overtemperature, Inverter Failure, IGBT SCR Fuse Failure, Bypass Overtemperature Failure, Inverter Output High / Low, Inverter Overtemperature
Front Panel Set Menu:
UPS Mode (UPS, ECO, Bypass Inhibit), DC Cut off, Low Battery Level, Output Voltage Adjustment, Set Output Frequency, Auto Start ON/OFF, Date, Alarm Sound ON/OFF, Password
Alarm Contacts (1 Open 1 Closed):
Inverter Failure, Overtemperature, Load on Bypass / Inverter, Inverter not Synchronized, DC Input Low /High, Battery Fuse OFF, Bypass out of Limit, Inverter Overload
Communication (OPTIONAL):
RS 485 / RS 232 / Ethernet Ports, Remote PC Control, Modbus, Profibus, SNMP, DNP 3.0 Protocols and TCP/IP options
Paralleling (OPTIONAL):
Parallel Redundancy
Bypass System:
No break semiconductor thyristor &ndash
Nominal Frequency:
50/60 Hz ±
Inverter/Bypass transfer time:
 
Inverter failure:
Max. 5 msec.
Overload or manual transfer:
0 msec.
Bypass/Inverter transfer time:
0 msec.
Over Voltage Protection:
IEEE 587 4500 A, 110 Joules (standard) / 40kA Surge Arrestor (OPTIONAL)
Electrical Interference Reduction:
FCC Part 15 Class B
Electrical Standards:
IEC 62040-3 (Performance), EN 50091-1 (Security) / EN 50091-2 (EMC)
Protection Level / Color:
IP 20 / RAL 7035 (Standard), (Higher IP rating and different colors are available, please consult)
MTBF:
100,000 hrs. (w/out battery group)
Enclosure Material:
Mild Steel, Zinc-phosphate coated
Cooling:
Forced Fan (Standard) / Natural (OPTIONAL)
Cable Entry:
Bottom (Standard) / Top (OPTIONAL)
Operating Temperature:
-10 / +40 °
Relative humidity:
5 &ndash
Operating Altitude:
Max. 1000 Mt. (Higher altitudes requires de-rating, please consult )